<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Computing, Telecommunication and Control</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Информатика, телекоммуникации и управление</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2687-0517</issn>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">1</article-id>
      <title-group>
        <article-title>Increase signal-to-noise ratio in acousto-optic spectrum analyzer with use astigmatic optics</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Увеличение отношения сигнал-шум в акустооптическом анализаторе спектра с использованием астигматической оптики</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Rogov</surname>
            <given-names>Sergey</given-names>
          </name>
          <email>sarogov@mail.ru</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Sergeev</surname>
            <given-names>Denis</given-names>
          </name>
          <email>enter_in_@rambler.ru</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Skorohod</surname>
            <given-names>Vladimir</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2012-06-10">
        <day>10</day>
        <month>06</month>
        <year>2012</year>
      </pub-date>
      <issue>3</issue>
      <issue-id pub-id-type="publisher-id">150</issue-id>
      <fpage>7</fpage>
      <lpage>12</lpage>
      <abstract xml:lang="en">
        <p>Shows the calculation of signal to noise ratio in acoustooptic spectrum analyzer with use astigmatic optical system to match the size of optical and ultrasonic beams. Improved method for calculating noise in optical systems with two-dimensional signals that are not functions with separable variables. The possibility of optimizing scheme of the spectrum analyzer to increase signal to noise ratio.</p>
      </abstract>